▪ Optical incremental scale with glass measuring support. Particularly suitable for applications on
synchronized press brakes.
▪ Reader head guided by a self-aligned and self-cleaning sliding carriage with spring system.
▪ Resolution up to 0.1 μm.
▪ Accuracy grade ± 2.5 μm in the standard version and ± 1 μm in the high-accuracy version.
▪ Metrological certificate provided with each scale.
▪ Reference indexes at coded distance or selectable every 10 mm along the entire measuring length,
with Zero Magneto Set device.
▪ The adjustable cable output and the selectable zero references make the scale SYMMETRIC and
applicable to both columns of the press brake.
▪ Safety limit switches, positionable at both ends.
▪ Sealing lips for the protection of the grating, made of special elastomer resistant to oil and wearing.
▪ Various possibilities of application, with double-effect joint or steel wire. An adapter guarantees the
compatibility with PBS-HR scale.
▪ High accuracy and stability of signals even in case of high speed, strong accelerations and vibrations.
▪ Moulded M12 connector (IP 67) or other models on request.
▪ Protected against inversion of power supply polarity and short circuits on output ports.
SCR3923
▪ Small overall dimensions. Rugged and heavy profile with a wide cross-section. Dimensions 39x23 mm.
▪ Armored connecting cable without external connections. Connector inside the transducer.
▪ Four sealing lips made of special elastomer resistant to wearing, for an excellent protection of the grating.
▪ High stability of LINE DRIVER signals.
▪ Resolutions up to 0.5 μm. Accuracy grade from ± 3 μm to ± 10 μm.
▪ Linear thermal expansion coefficient λ = 10.6 x 10-6 °C-1 suitable for the application.
▪ One reference index at midpoint or in different required positions.
▪ Wide alignment tolerances.
▪ In modular version for measuring lengths over 6,500 mm, or for lower measuring lengths on request.
▪ Full possibility to disassemble and reassemble the scale.
▪ Protected against inversion of power supply polarity and short circuits on output ports.
NCS
▪ Optical scale with glass measuring support, particularly suitable for CNC machines.
▪ Resolutions up to 0.1 μm.
▪ Accuracy grade ± 3 μm in the standard version and ± 1 μm in the high-accuracy version.
▪ Metrological certificate provided with each scale.
▪ Four sealing lips made of special elastomer resistant to wearing, for an excellent protection of the grating.
▪ Linear thermal expansion coefficient λ = 8 x 10-6 °C-1.
▪ Adjustable connecting cable output. Connector inside the transducer.
▪ Reference indexes at coded distance, or at constant step, with predetermined or selectable positions.
▪ High accuracy and stability of signals even in case of high speed, strong accelerations and vibrations.
▪ Protected against inversion of power supply polarity and short circuits on output ports.
▪ Small size, to allow installation in narrow spaces.
ISA 2320
▪ Reduced size, to allow installation on small machine-tools or for applications with limited installation space.
▪ Possibility of registration which simplifies alignment and allows the use on rough surfaces
(retrofitting and machines for which application was not foreseen).
▪ Resolutions up to 0.5 μm. Accuracy grade from ± 3 μm to ± 10 μm.
▪ Linear thermal expansion coefficient λ = 10.6 x 10-6 °C-1 suitable for the application.
▪ Reference indexes in required positions.
▪ Protected against inversion of power supply polarity and short circuits on output ports.
GVS204
▪ Absolute optical scale with glass measuring support. Particularly suitable for applications on
synchronized press brakes.
▪ Serial interface SSI-BiSS, with or without 1 Vpp analog signal.
▪ Reader head guided by a self-aligned and self-cleaning sliding carriage with spring system.
▪ Resolution up to 0.1 μm.
▪ Accuracy grade ± 2.5 μm in the standard version and ± 1 μm in the high-accuracy version.
▪ SSI protocol and programmable resolutions.
▪ Profibus-DP, Profinet, CANopen, DeviceNet, ModBus and DRIVE-CLiQ protocols, through
conversion gateways.
▪ Metrological certificate provided with each scale.
▪ Sealing lips for the protection of the grating, made of special elastomer resistant to oil and wearing.
▪ Various possibilities of application, with double-effect joint or steel wire. An adapter guarantees
the compatibility with PBS-HR scale.
▪ High accuracy and stability of signals even in case of high speed, strong accelerations and vibrations.
▪ Protected against inversion of power supply polarity and short circuits on output ports.
AGS
▪ Absolute optical scale with glass measuring support, particularly suitable for CNC machines.
▪ Serial interface SSI-BiSS, with or without 1 Vpp analog signal.
▪ Resolutions up to 0.1 μm.
▪ Accuracy grade ± 3 μm in the standard version and ± 1 μm in the high-accuracy version.
▪ SSI protocol and programmable resolutions.
▪ Profibus-DP, Profinet, CANopen, DeviceNet, ModBus and DRIVE-CLiQ protocols, through conversion gateways.
▪ Metrological certificate provided with each scale.
▪ Linear thermal expansion coefficient λ = 8 x 10-6 °C-1.
▪ High accuracy and stability of signals even in case of high speed, strong accelerations and vibrations.
▪ Adjustable connecting cable output.
▪ Connector inside the transducer.
▪ Protected against inversion of power supply polarity and short circuits on output ports.
▪ Small size, to allow installation in narrow spaces.
GMS
▪ Modular optical scale with stainless steel grating, particularly suitable for long strokes (measuring length up to 30,040 mm).
▪ Rugged and heavy profile, in anodized aluminium.
▪ Coupling gaskets between the modules for a better fit of mechanical parts (in case of disassembly and reassembly).
▪ Resolutions up to 0.1 μm.
▪ Accuracy grade ± 10 μm.
▪ Linear thermal expansion coefficient λ = 10.6 x 10-6 °C-1 suitable for the application.
▪ Reference indexes at coded distance, or at constant step (50 mm) or selectable.
▪ Sine-wave or TTL signal output.
▪ Protected against inversion of power supply polarity and short circuits on output ports.