▪ Optical scale with glass measuring support, particularly suitable for CNC machines.
▪ Resolutions up to 0.1 μm.
▪ Accuracy grade ± 3 μm in the standard version and ± 1 μm in the high-accuracy version.
▪ Metrological certificate provided with each scale.
▪ Four sealing lips made of special elastomer resistant to wearing, for an excellent protection of the grating.
▪ Linear thermal expansion coefficient λ = 8 x 10-6 °C-1.
▪ Adjustable connecting cable output. Connector inside the transducer.
▪ Reference indexes at coded distance, or at constant step, with predetermined or selectable positions.
▪ High accuracy and stability of signals even in case of high speed, strong accelerations and vibrations.
▪ Protected against inversion of power supply polarity and short circuits on output ports.
▪ Small size, to allow installation in narrow spaces.
NCS T05 Output TTL – Resolution 0.5 μm | |
| Resolution | 0.5 µm |
| Grating pitch | 20 µm |
| Accuracy grade | ± 3 µm standard ± 1 µm high-accuracy |
| Max. traversing speed | 120 m/min |
| Measuring length | from 70 up to 3,240 mm |
| Reference indexes | coded distance / constant step / selectable |
| Output signals | LINE DRIVER / PUSH-PULL |
| Protection class | IP 54 standard IP 64 pressurized |
NCS T01 Output TTL – Resolution 0.1 μm New | |
| Resolution | 0.1 µm |
| Grating pitch | 20 µm |
| Accuracy grade | ± 3 µm standard ± 1 µm high-accuracy |
| Max. traversing speed | 45 m/min |
| Measuring length | from 70 up to 3,240 mm |
| Reference indexes | coded distance / constant step / selectable |
| Output signals | LINE DRIVER / PUSH-PULL |
| Protection class | IP 54 standard IP 64 pressurized |